{"id":286,"date":"2015-09-28T13:48:08","date_gmt":"2015-09-28T20:48:08","guid":{"rendered":"http:\/\/blog.gptnet.net\/?p=286"},"modified":"2015-09-28T13:53:07","modified_gmt":"2015-09-28T20:53:07","slug":"hp-proliant-bl460c-gen9-hba-bug","status":"publish","type":"post","link":"http:\/\/blog.gptnet.net\/?p=286","title":{"rendered":"HP Proliant BL460c Gen9 HBA bug"},"content":{"rendered":"<p>There is a bug with HP FlexFabric 650FLB adapters on HP Gen 9 blades. Buggy firmware prevents HBA from properly negotiating FC protocols. HBA will fail to initiate the PLOGI (Port Login) process. Symptoms on Brocade FC switch will show FC4 type as &#8220;none&#8221; and switch would fail to detect it as initiator.<br \/>\nIf you have Brocade switch it can be confirmed via <em>portloginshow #<\/em> command, where # is the port number where blade is connected.<\/p>\n<blockquote><p>fctest:admin&gt;portloginshow 1<br \/>\nType PID World Wide Name credit df_sz cos<br \/>\n=====================================================<br \/>\nfd 01153b xx:xx:xx:xx:xx:c2:86:04 16 2112 c scr=0x3<br \/>\nfd 011537 xx:xx:xx:xx:xx:c2:86:14 16 2112 c scr=0x3<br \/>\nff 01153b xx:xx:xx:xx:xx:c2:86:04 0 0 8 d_id=FFFFFC<\/p><\/blockquote>\n<p>d=id=FFFFC will be missing for faulty HBA. I the example above HBA ending with c2:86:14 has frmware with the bug.<\/p>\n<p>Issue is confirmed with 10.5.65.21 (latest available on HP website)<br \/>\nResolution: update firmware to 10.5.65.23<\/p>\n<p>You can download firmware below (it&#8217;s not available via HP website yet)<br \/>\n<a href=\"http:\/\/blog.gptnet.net\/wp-content\/uploads\/2015\/09\/OneConnect-Flash-10.5.65.23.zip\">OneConnect-Flash-10.5.65.23<\/a><\/p>\n<p>Update: HP issued advisory:<\/p>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: black; font-family: Arial, sans-serif; font-size: large;\"><strong>Environment<\/strong><\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: blue; font-family: 'Courier New'; font-size: medium;\"><strong>FACT:<\/strong><\/span><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">HP ProLiant BL460c Gen9 Server<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: blue; font-family: 'Courier New'; font-size: medium;\"><strong>FACT:<\/strong><\/span><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">HP FlexFabric 20Gb 2-port 650M Adapter<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: blue; font-family: 'Courier New'; font-size: medium;\"><strong>FACT:<\/strong><\/span><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">HP FlexFabric 20Gb 2-port 650FLB Adapter<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: black; font-family: Arial, sans-serif; font-size: large;\"><strong>Questions\/Symptoms<\/strong><\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: #995533; font-family: 'Courier New'; font-size: medium;\"><strong>SYMPTOM: <\/strong><\/span><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">Storage path will disappear after the Firmware upgrade to 10.5.65.21<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: #995533; font-family: 'Courier New'; font-size: medium;\"><strong>SYMPTOM: <\/strong><\/span><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">Problem is seen with VIrtual Connect Manager and OneView enviornments<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: #995533; font-family: 'Courier New'; font-size: medium;\"><strong>SYMPTOM: <\/strong><\/span><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">Storage path may disappear after 650FLB Firmware upgrade to 10.5.65.21<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: #995533; font-family: 'Courier New'; font-size: medium;\"><strong>SYMPTOM:<\/strong><\/span><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">P roblem is seen with Virtual Connect FLexfabric 10\/24 and 20\/40 modules<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">\u00a0<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">Upgrading with latest firmware (10.5.65.21) on 650 FLB may cause the path to the storage to disappear. This issue may occur when using the latest SPP Version 2015.06.0.<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: black; font-family: Arial, sans-serif; font-size: large;\"><strong>Cause<\/strong><\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: red; font-family: 'Courier New'; font-size: medium;\"><strong>CAUSE: <\/strong><\/span><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">This issue only occurs because of the 650FLB firmware version 10.5.65.21<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: black; font-family: Arial, sans-serif; font-size: large;\"><strong>Answer\/Solution<\/strong><\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: #aa00aa; font-family: 'Courier New'; font-size: medium;\"><strong>FIX: <\/strong><\/span><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">This issue is currently under investigation<\/span><\/span><\/div>\n<div><span style=\"font-family: Calibri, sans-serif; font-size: small;\"><span style=\"color: black; font-family: 'Courier New'; font-size: medium;\">As Workaround downgrade the firmware to 10.2.477.23 using (SPP) Version 2015.04.0 Or Reduce the uplink to 1 per Virtual connect SAN fabric or OneView Fibre Channel Uplink set.<\/span><\/span><\/div>\n","protected":false},"excerpt":{"rendered":"<p>There is a bug with HP FlexFabric 650FLB adapters on HP Gen 9 blades. Buggy firmware prevents HBA from properly negotiating FC protocols. HBA will fail to initiate the PLOGI (Port Login) process. Symptoms on Brocade FC switch will show &hellip; <a href=\"http:\/\/blog.gptnet.net\/?p=286\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[77,78,75,80,68,76,79],"class_list":["post-286","post","type-post","status-publish","format-standard","hentry","category-random-stuff","tag-10-5-65-23","tag-650flb","tag-bl460-g9","tag-blade","tag-bug","tag-hba","tag-proliant"],"_links":{"self":[{"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=\/wp\/v2\/posts\/286","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=286"}],"version-history":[{"count":6,"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=\/wp\/v2\/posts\/286\/revisions"}],"predecessor-version":[{"id":293,"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=\/wp\/v2\/posts\/286\/revisions\/293"}],"wp:attachment":[{"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=286"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=286"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/blog.gptnet.net\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=286"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}